OYSTER CREEK

Permanent Shutdown


Reactor Details

Reactor Type Model Owner Operator
BWR
BWR-2 (Mark 1)
Exelon Corporation
Exelon Generation Co., LLC
Reference Unit Power (Net Capacity) Design Net Capacity Gross Capacity Thermal Capacity
619 MWe
650 MWe
652 MWe
1930 MWt
Construction Start Date First Criticality Date
15 Dec, 1964
03 May, 1969
First Grid Connection Commercial Operation Date
23 Sep, 1969
01 Dec, 1969
Permanent Shutdown Date
17 Sep, 2018

LifeTime Performance

Electricity Supplied Energy Availability Factor Operation Factor Energy Unavailability Factor Load Factor
196.20 TW.h
78.5 %
78.2 %
21.5 %
74.2 %
Lifetime performance calculated up to year 2018

Operating History

Year Electricity Supplied
[GW.h]
Reference Unit Power
[MW]
Annual Time On Line
[h]
Operation Factor
[%]
Energy Availability Factor
[%]
Load Factor
[%]
Annual Cumulative Annual Cumulative
1969 Data Not Provided
1970 3591.000 540 6788 77.5 100.0 100.0 75.9 75.9
1971 3972.600 595 7046 80.4 100.0 100.0 76.2 76.1
1972 4503.800 670 7137 81.2 100.0 100.0 76.5 76.2
1973 3589.000 620 6401 73.1 73.8 93.3 66.1 73.6
1974 3679.600 650 6163 70.4 66.6 87.7 64.6 71.7
1975 3148.700 610 6414 73.2 59.1 82.9 58.9 69.6
1976 3860.100 620 6966 79.3 70.9 81.2 70.9 69.8
1977 3249.200 620 6136 70.0 59.9 78.5 59.8 68.6
1978 3645.700 620 6508 74.3 66.5 77.2 67.1 68.4
1979 4563.300 620 7520 85.8 83.8 77.8 84.0 70.0
1980 1957.300 620 3662 41.7 41.8 74.6 35.9 66.8
1981 2628.900 620 5237 59.8 59.9 73.3 48.4 65.3
1982 2013.000 620 5474 62.5 62.5 72.5 37.1 63.1
1983 225.500 620 1007 11.5 11.5 68.1 4.2 58.9
1984 305.190 620 842 9.6 9.6 64.2 5.6 55.3
1985 3746.030 620 6518 74.4 74.5 64.8 69.0 56.2
1986 1317.690 620 2310 26.4 26.7 62.6 24.3 54.3
1987 3113.390 620 5421 61.9 62.0 62.6 57.3 54.5
1988 3547.300 620 5749 65.4 65.5 62.7 65.1 55.0
1989 2410.110 620 4686 53.5 53.6 62.3 44.4 54.5
1990 4305.050 620 7678 87.6 87.7 63.5 79.3 55.7
1991 2954.840 610 5167 59.0 59.0 63.3 54.5 55.6
1992 4531.840 610 7463 85.0 84.9 64.2 84.6 56.9
1993 4667.480 610 7654 87.4 87.4 65.2 87.4 58.1
1994 3633.280 619 6096 69.6 69.2 65.3 67.9 58.5
1995 5194.080 619 8511 97.2 97.2 66.5 95.8 59.9
1996 4339.400 619 7104 80.9 80.9 67.1 79.8 60.7
1997 5073.280 619 8164 93.2 93.2 68.0 93.6 61.9
1998 4302.230 619 7094 81.0 81.0 68.5 79.3 62.5
1999 5388.510 619 8760 100.0 100.0 69.5 99.4 63.7
2000 3908.200 619 7073 80.5 80.6 69.9 71.9 64.0
2001 5226.370 619 8497 97.0 97.0 70.7 96.4 65.0
2002 5031.270 619 8215 93.8 93.8 71.4 92.8 65.8
2003 5256.320 619 8468 96.7 96.7 72.2 96.9 66.7
2004 4846.970 619 7973 90.8 90.8 72.7 89.1 67.4
2005 5374.910 619 8706 99.4 99.4 73.4 99.1 68.3
2006 4644.530 619 7775 88.8 88.8 73.9 85.6 68.7
2007 5077.930 619 8435 96.3 96.3 74.4 93.6 69.4
2008 4664.010 619 7924 90.2 90.2 74.8 85.8 69.8
2009 4978.400 614 8320 95.0 95.0 75.4 92.6 70.4
2010 4604.970 614 7661 87.4 87.5 75.6 85.6 70.7
2011 5298.450 619 8541 97.5 97.5 76.2 97.7 71.4
2012 4718.190 619 7663 87.2 88.5 76.5 86.8 71.8
2013 5116.690 619 8324 95.0 95.0 76.9 94.4 72.3
2014 4833.530 619 7859 89.7 89.7 77.2 89.1 72.6
2015 5275.790 619 8484 96.8 96.8 77.6 97.3 73.2
2016 4585.200 619 7553 86.0 86.0 77.8 84.3 73.4
2017 5429.570 619 8703 99.4 99.4 78.2 100.1 74.0
2018 3540.310 619 6227 99.8 97.0 78.5 91.7 74.2
Performance indicators are calculated from the Commercial Operation Date.


Above data generated by the PRIS database. Last update on 2024-12-04